All Green Insulation™ aluminium reflective foil bubble and foam insulation products have been extensively tested. All insulation tests are performed at nationally approved independent laboratories with accreditation from NATA (National Assoc. of Testing Authorities) as well as leading universities across Australia. Our products conform to the latest insulation standard AS/NZS 4859.1-2002/Amdt 1 (Dec 2006).

Results of following tests on Reflecta-Guard and Reflecta-Cell are provided below:

  • Material test
  • Fire Test
  • Acoustic Test
  • Fall Arrest

Material Test Green Insulation reflective aluminium foil and foam insulation

   
Results
Test Type
Standard Type

Reflecta-Cell®

Reflecta-Guard™

Reflecta-Break™

Material Thermal Resistance (Rm) ISO 8302-1991 0.14m².K/W 0.24m².K/W 0.24m².K/W
Resistance to Dry Delamination AS/NZS 4201.1-1994 Pass Pass Pass
Resistance to Wet Delamination AS/NZS 4201.2-1994 Pass Pass Pass
Shrinkage AS/NZS 4201.3-1994 Pass (0.2%) Pass (0.1%) Pass (0.1%)
Water Barrier AS/NZS 4201.4-1994 High High High
Duty Classification AS/NZ 4200.1-1994 Heavy Duty Extra Heavy Duty Extra Heavy Duty

Fire Test Green Insulation reflective aluminium foil and foam insulation

Fire test results are based on AS 1530.3-1999

 
Results
Test Type

Reflecta-Cell®

Reflecta-Guard™

 Reflecta-Break™

Ignitability Index 0 0 0
Spread of Flame Index 0 0 0
Heat Evolved Index 0 0 0
Smoke Developed Index 1 0-1 0-1
Flammability Index <5 <5 <5
Download fire certificates for each product below

Reflecta-Cell™ - Fire | AS 1530.2-1993

Reflecta-Guard™ - Fire | AS 1530.2-1993

Acoustic Insulation Test Green Insulation reflective aluminium foil and foam insulation

All the tests were conducted in accordance to the following Australian Standards.
ISO 354-2003: Acoustics: Measurement of sound absorption in a reverberation room.
AS ISO 11654 – 2002: Acoustics: Rating of sound absorption – Materials and systems.
AS 1191 – 2002: Acoustics: Method for laboratory measurement of airborne sound insulation of building elements.
AS/NZS ISO 717.1:2004 Acoustics: Rating of sound insulation in buildings and of building elements.

 

Reflecta-Cell®

Reflecta-Guard™

Frequency

Sound reduction in dB

Sound reduction in dB

1000

9

9

3150

14

21

4000

19

27

5000

24

35

STC or Rw values (Standalone)
Test Type

Reflecta-Cell®

Reflecta-Guard™

Sound Transmission Class (STC) 10 11

STC was calculated based on the test performed by Mechanical Engineering Testing & Consulting at the University of Adelaide. Once Green Insulation™ is installed within plasterboard or brick veneer walls. Our STC values are competitive to the sound barrier products in market.

Fall arrest Properties

Reflecta-Cell and Reflecta-Guard reflective aluminium bubble foil insulation both use a double high strenth scrim to deliver the toughest, strongest and most durable foil insulation available anywhere.

To test the performance of Green Insulation™ to be used as a fall arrest barrier, tests were conducted in accordance with the Australian Standard AS4040.4–2006: (Resistance to impact). The test is intended to simulate the accidental falling of a person onto a plastic building sheet incorporated into a roof structure. The test method specifies a bag with a nominal 300mm diameter base, filled with 25kg of dry sand to be dropped from a height of 2.5m above the impact position of the specimen.

Compliance:

Reflecta-Guard™ & Reflecta-Cell® resisted impact of a 25kg sandbag from a drop height of 2.5 metres, at the first impact position, when laid over a metal roof with purlins set at a 1500mm span at both 0 and 18 degrees roof pitches. This included the use of fasteners, 10gx40mm wafer-head self drilling screws, spaced at a nominal 160mm centres, using 50mm flat washers, along the width of the material or sheet end at the roof edge or end purlin.

Fasteners and washers were also located at every other purlin, at the sheet edge. The insulation material was fixed to the roof structure to give a 50mm sag at the span midpoint, below the horizontal plane of the top face of the purlin.
Green Insulation™ strongly recommends that you refer to your local Occupational Health and Safety guidelines, to use our products as a fall arrest.

 

Important note about Reflecta-Shed. We do not provide test results for Reflecta-Shed. Reflecta-Shed uses similar outside aluminium layers, and also our patented protective coating. The main differentiation between Reflecta-Shed insulation and our other products is that it does not include the centre fire retardant. Reflecta-Shed is NOT compliant for BCA uses. However, Reflecta-Shed is a purpose manufactured high quality, high performance foil insulation specifically designed for value when insulating sheds. Most sheds constructed privately do not need to be BCA compliant, Reflecta-Shed is your best alternative here.

Green Insulation offer a range of support services for their foil insulation products. Should you need support, please contact us. PH. (07) 3200 6522

Green Insulation operate 8:30am to 5pm Monday to Friday E.S.T. excluding public holidays. We suggest the following contacts may be of value.

Free Engineer support. Whether you are specifying reflective foil insulation or you need other technical advice, please contact us:  This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it

For the best customer support in the industry, please contact us! This e-mail address is being protected from spambots. You need JavaScript enabled to view it

Photo Gallery

Gallery

Contact Us

Unit 1/13 Meakin Road, Meadowbrook Qld 4131

Phone:+ 61 (0)7  3200 6522
Fax: + 61 (0)7 3200 6599
Map: View Google Map
Email us: contact@greeninsulation.com.au